Alarm kit
Table of Contents

Advertisement

4

Mounting alarm devices

WARNING To prevent the alarm from activating during installation, the siren must have its
tamper disabled and the control panel must be in 'Walk Test'/Programme mode.
Control Panel Mounting
Table top
Remove the mounting back plate (if fitted) and
simply place on top of a table on its rubber feet.
• If the mounting plate has been fitted with the
power on, the control panel will show a panel
tamper condition when the plate is removed. To
cancel make sure that the mounting plate is not
fitted and power down by removing the power
plug and switching off the battery. Reconnect
power and switch the battery back on. The panel
tamper will be reset and not activate again unless
the plate is put back on.
Wall Mounting
Using the two holes on the mounting back plate,
mark the position of the holes. Drill two holes and
fix with the screws and plugs provided. Hook the
control panel onto the plate. Ensure that the control
panel is fitted at approximately chest height where
the display can be easily seen and the keypad
convenient to operate.
• The control panel tamper protection will
automatically arm when mounted on the back
plate.
Disabling the system tamper
i
Before mounting it is important to disable the
siren and system tamper to avoid the siren
sounding an alarm.
1 Press the
key and enter a user PIN code
followed by 3.
2 The control panel is now in programming mode,
Select Devices +/-, then Program Siren and
Siren Tamp. Off using the pq3 keys.
3 Press 3 when in the Siren Tamp. Off menu
and the control panel will beep followed by an
acknowledgement pip from the siren.
• Siren programming is described more fully
in "Control Panel Menu System in Detail" in
section 5.
• The siren tamper will now be disabled for 1
hour after which it will automatically arm again.
If longer is needed to fit the siren then simply
repeat the steps above.
• Leave the control panel in programming
mode to stop the system responding to
tampers. If the control panel automatically
times out, re-enter programming mode
again.
Mounting the siren
Ensure the tamper switch is fully depressed when
the siren is mounted. If there is a gap, pack with a
suitable spacing material.
Spring compressed
firmly against wall
Round
Wall
Siren
Base
Spring Guide
1 Find a location where the siren is to be mounted.
2 Using the large screws and wall plugs provided,
screw the siren onto the wall through the 4
mounting holes on the siren base.
3 Fix the siren cover with the securing screw.
4 Using the Programming Devices +/- menu enable
the siren tamper (see the end of this section "Final
step:") and Arm and Disarm the system with the
control panel.
5 If there are 5 short beeps when armed, the tamper
switch is NOT fully depressed and will need to be
adjusted.
Unset the system and disable the siren tamper as
described above before adjusting the siren tamper
switch. If there is a gap between the wall and the
tamper switch mechanism, pack with a suitable
spacing material.
When adjusted repeat the steps above from steps
3 through 5.
6 If there is one short beep and flash when armed,
the siren is mounted correctly and the siren
installation is complete.
Wall
Plunger must
be pressed in
fully against
wall