Mounting other devices
Find a location where the device is to be mounted,
see section "Location Planning" for suggestions.
i
Before proceeding to mount the devices
physically, check that the control panel will
receive the system radio transmissions by
doing a simple radio range test.
• Put the control panel into walk test mode.
• KEYPAD: press the arm button.
• HELP BUTTON: press the button.
• ALL OTHER DEVICES: Hold the device
in the desired location and press the
learn/test button, the control panel should
respond with a chime.
• When you are satisfied that the devices
work in your chosen locations, proceed
with the installation as described.
• If the control panel does not respond,
the location may be out of range, try
alternative locations until reliable radio
contact is obtained.
Mounting the Keypad:
Fixing Slots X 2
Keypad
Cradle Open
1 Drill holes into the wall using the fixing slots as a
template.
2 Fit wall plugs into the wall and fix cradle with the
screws provided.
10
3 Slide the keypad into the cradle
4 Close the cradle cover so the logo is facing you
Mounting the PIR motion detector
1 Open the PIR by loosening the bottom screw.
Knock out the relevant holes on the base where
the plastic is thinner. The center two knockout
holes are for flat wall mounting while the 4 side
holes are for corner mounting.
Wall fixing
knockouts X 2
Corner fixing
knockouts X 4
2 Drill holes into the wall using the knockout holes on
the base as a template.
3 Fit wall plugs and secure the PIR base with the
screws provided.
4 Fit the PIR back together and tighten bottom
screw, the PIR installation is complete.
i
The PIRs have a built-in sleep timer to save
battery power. If there is no movement in front
of the PIRs for 1 minute, the PIRs will become
'ready to signal' and movement will now be
reported. The PIRs will sleep for 1 minute after
reporting.
Any movement detected in sleep time will not be
reported and will extend the sleep period by a
further 1 minute.