Control Panel Menu System In Detail - Assa Abloy Premium Plus HSA6410 Installation, Programming, Operating Manual

Alarm kit
Table of Contents

Advertisement

5

Control Panel Menu System in Detail

Entering Programming Mode
The programming mode is for you to configure
the system, and make any changes to the pre-set
functions.
If the system is in Disarmed (Alarm off) mode, follow
the steps below to enter the programming mode.
1 Press
key on the function key list.
The screen will prompt you to enter the PIN code.
P - M o d e
P - C o d e
2 Key in your PIN code within 30 seconds.
Note
• By pressing X this will clear the entered PIN. If the
code field is empty, press X. The screen will then
exit and return to the Alarm Off screen.
3 Press 3 to continue.
The following message is displayed for 2 seconds.
P r o g r a m
M a k e
a
4 Then the Programming Main Menu will typically be
displayed.
* W a
l
k
D e v
i
c e + /
Note
• The cursor is indicated by a flashing dot on the left
upper corner. It can be moved up and down by
pressing pq respectively.
5 The following items can be selected:
·
Fault log (appears only if there is a fault
condition in your system)
·
Walk Test
·
Devices +/-
·
Log
·
Adv. Settings
·
Tel. Settings
·
Contactless
6 After making a selection by moving the cursor
to the desired item, press 3 to confirm the
selection. The display will show you the individual
programming screen accordingly.
Note
• If a down-arrow symbol q appears on the last
column of the screen, it indicated the selection list
can be scrolled downwards. If the lowest position
12
e n t e r
.
.
.
.
m e n u
s e
l
e c t
i
o n
t e s
t
-
à
is reached, the down-arrow symbol q disappears.
• If an up-arrow symbol p appears on the last
column of the screen, it indicated the selection list
can be scrolled upwards. If the highest position is
reached, the up-arrow symbol p disappears.
• Selecting X will return to the Alarm Off screen.
Important Note
• In programming mode, if no key is pressed within
5 minutes, the control panel will automatically exit
the programming mode and return to the Alarm
Off screen.
Walk Test
When Walk Test is selected, three beeps will sound
during a screen self test. This allows you to test the
system without causing an alarm. To test the control
panel is receiving a signal, do one of the following
depending on the device:
1 Press any arm button on the remote keyfob or
keypad
2 Press the test button on the sensor
3 Press the panic button
A chime will sound and the display will show you
which device is transmitting.
The message will be displayed until replaced by
another test transmission.
• The external siren can be tested by arming and
disarming the system, the siren will respond as
below.
· When the control panel is armed, the strobe light
will flash and beep once.
· When the control panel is disarmed, the siren
will give two short beeps and the strobe will flash
from side to side twice.
Device +/-
Select 'Devices +/-' in the main programming menu
to add or remove a device. From here you will be
able to view a list of all the devices being installed
and you can add or delete devices. The following
items can be selected.
· Add Device
· Edit Devices
· Remove Device
· Program Siren