Basic Safety − Sto; Mode Of Operation - Lenze E70AC Series Hardware Manual

Servo-inverter
Table of Contents

Advertisement

10.6
Basic Safety − STO
E70ACMxxxxx4xAxETx − Basic Safety − STO
10.6.1

Mode of operation

With the integrated safety system, product key: A, the following safety function can be
used:
Safe Torque Off (STO)
ƒ
If requested, the safe disconnection of the drive is achieved through:
Directly connected active sensors
ƒ
Passive sensors connected to a safety switching device
ƒ
The safety functions are suitable for applications according to IEC 61508 to SIL 3 and
achieve a performance level (PL) e and the control category 4 according to EN ISO 13849−1.
}
Danger!
If the request for the safety function is cancelled, the drive will restart
automatically.
You must provide external measures which ensure that the drive only restarts
after a confirmation (EN 60204).
The transmission of the pulse width modulation is safely switched (off) by the safety unit.
After this, the power drivers do not generate a rotating field. The motor is safely switched
to torqueless operation (STO).
µC
PWM
Fig. 10−1
Safety status
If the controller is switched off by the safety system, the "STO is not active" status in the
status word changes from 1: HIGH to 0: LOW (object 0x6041/0x6841, bit 15).
EDS700ACBA EN 5.1
X...
SU
3x
3x
Operating principle of safety unit
SU
Safety unit
X...
Control terminals of the safety unit
mC
Microcontroller
PWM
Pulse Width Modulation
M
Motor
l
Safety engineering
Basic Safety − STO
Mode of operation
M
10
i700FP005