Lenze E70AC Series Hardware Manual page 54

Servo-inverter
Table of Contents

Advertisement

4
Technical data
Terminal description
Axis modules
External voltage supply
X3
Terminal data
flexible
X3
Electrical data
24E
Rated voltage
GE
Voltage range
Residual ripple
Current consumption
Polarity reversal
protection
Cable protection
GND-I
X3
GE 24E
DC 24 V
(+19.2...+28.8 V)
Fig. 6
54
Labelling
24E
GE
i700P00x
Conductor cross−section
2
[mm
]
0.2 ... 2.5
24 V
19.2 ... 28.8 V
Max. ± 5 %
See technical data, ^ 4.2.1
When polarity is reversed: no function and no
destruction.
Circuit breaker with tripping characteristic B or C
Standard blade−type fuses
X21, X3
Wiring of X3
X3
Supply voltage connection of axis module control electronics, can be looped
through
24E
DC 24 V, acc. to IEC 61131−2, SELV/PELV
GE
Reference potential GND
l
Description
24−V supply voltage of control electronics from a safely separated
power supply unit (SELV/PELV)
Reference potential (GND)
Tightening torque
[AWG]
[Nm]
24 ... 12
!
[lb−in]
3.5 x 0.6
in accordance with
IEC 61131−2
i700M00x