Lenze E70AC Series Hardware Manual page 10

Servo-inverter
Table of Contents

Advertisement

1
About this documentation
Terms and abbreviations used
Term
C
L
f
f
Ch
I
aMx
I
aNdc
I
aNx
I
BRd
I
BRmax
I
max_3
I
max_60
I
red_12
I
red_120
I
r4
I
r24
I
max24
P
24
P
Bd
P
loss
R
Bmin
P
BRmax
t
fp
t
on
t
Z
U
Lrated
U
DC
DC−bus operation
Term
DC bus
DC bus
DC−voltage level
Power supply module
Regenerative power supply module
Multi−axis controllers (Multi Drive)
Single−axis controllers (Single Drive) Controllers for connection to an AC mains or a DC bus. Single−axis
Brake chopper
Brake resistor
Braking operation
10
Description
Loading capacity for the 24 V supply
Frequency or frequency range
Switching frequency
Max. output current
Rated value of continuous output current of the power supply module
Rated value of continuous output current, frequency−dependent
Continuous current RMS − important for the dimensioning of the cables
Peak current
Maximum short−time current after cycle time
Maximum short−time current after cycle time
Reduced current after cycle time (recovery phase)
Reduced current after cycle time (recovery phase)
Rated value of continuous output current at 4 kHz
Rated current for the 24 V supply
Maximum current for the 24 V supply
Rated power for the 24 V supply
Continuous braking power
Power loss
Nominal value of minimum brake resistance
Peak braking power
Maximum running time without initial load and compliance with the
recovery time
Running time
Cycle time, periodic load change with running time and recovery time
Rated mains voltage, also voltage range
Rated DC bus voltage, also voltage range
Description
The energy store in the controller or supply module from which the
controller modulates the AC voltage for the motor. The DC buses of several
controllers can be networked.
Electrical connection of the DC connections of several controllers via cable
or busbar.
DC−voltage level in the DC bus
Module with AC mains connection used to supply the DC bus of a drive
system with DC voltage.
Power supply module with additional power regeneration into the AC
mains
Controllers for connection to a DC bus. Multi−axis controllers have no AC
mains connection and no brake chopper.
controllers have an integrated brake chopper.
Switching element in the controller used to dissipate excess energy in the
DC bus via a brake resistor.
High−performance resistor used to convert excess energy in the DC−bus
into heat.
Motor operation in generator mode with energy feedback from the motor
to the controller.
l