Resolver
X7
X7
Electrical data
General
3
n. c.
1, 2
+REF, −REF
4, 5
+COS, −COS
6, 7
+SIN, −SIN
8, 9
+KTY, −KTY
EDS700ACBA EN 5.1
Pin
Description
E70ACM...R
1
+REF
2
−REF
3
n. c.
4
+COS
5
−COS
6
+SIN
7
−SIN
8
+KTY
9
−KTY
"
Shield connection at Sub−D housing
i700AX007 a b
Cable length (system cable is recommended)
Input frequency
Excitation voltage
Carrier frequency
Type
l
Technical data
Terminal description
Axis modules
On single axis devices, this
connection is located on the
right−hand side below the labelling
"X7".
On double axis devices, there are two
of these connections. For the
assignment to the axes, the
designations "A" / "B" are used.
Max. 50 m
max. 250 kHz
10 V
SS
4 kHz, constant value
KTY 83−110
4