LP 471 UVA
Radiometric probe for IRRADIANCE measurement complete with SICRAM
module; in the 315 nm...400 nm, peak 360 nm, UVA spectral range, quartz
diffuser for cosine correction. Measurement range: 1⋅10
LP 471 UVB
Radiometric probe for IRRADIANCE measurement complete with SICRAM
module, in the 280 nm...315 nm, peak 305 nm, UVB spectral range, quartz
diffuser for cosine correction.
Measurement range: 1⋅10
LP 471 UVC
Radiometric probe for IRRADIANCE measurement complete with SICRAM
module, in the 220 nm...280 nm, peak 260 nm, UVC spectral range, quartz
diffuser for cosine correction. Measurement range: 1⋅10
LP 32 F/R
Support bracket for photometric-radiometric probes for Light measurement
LP471...
14.2.5 Probes for CO
HD320B2
MINICAN.12A
MINICAN.12A1
HD37.37

14.2.6 Probes for the measurement of CO carbon monoxide complete with SICRAM module

HD320A2
HD320AS2
MINICAN.12A
MINICAN.12A1
HD37.36
DELTA OHM metrology laboratories LAT N° 124 are ISO/IEC 17025 accredited by
ACCREDIA for Temperature, Humidity, Pressure, Photometry / Radiometry, Acoustics and
Air Velocity. They can supply calibration certificates for the accredited quantities.
HD32.1
carbon dioxide measurement complete with SICRAM module
2
Probe for the measurement of CO
module, with double source infrared sensor. Measurement range:
0...5000ppm. Cable L=2m.
Nitrogen cylinder for CO
adjusting valve.
Nitrogen cylinder for CO
adjusting valve.
Kit for connection tube between the probe and MINICAN.12A for CO
calibration.
Probe for the measurement of CO carbon monoxide complete with SICRAM
module, with electro chemical sensor endowed with two electrodes.
Measurement range: 0...5000ppm. Cable L=2m.
Magnetic support for fixing the HD320A2 probe to HD320B2 probe body.
Nitrogen cylinder to calibrate CO at 0ppm. Volume 20 litres. With adjusting
valve.
Nitrogen cylinder to calibrate CO at 0ppm. Volume 20 litres. Without
adjusting valve.
Kit for connection tube between the sensor and MINICAN.12A for the
calibration of CO.
-3
2
2
W/m
...2000 W/m
carbon dioxide complete with SICRAM
2
calibration at 0ppm. Volume 20 litres. With
2
calibration at 0ppm. Volume 20 litres. Without
2
- 152 -
-3
2
W/m
...2000 W/m
.
-3
2
W/m
...2000 W/m
2
.
2
.
2
V2.1