HP474ACR
Combined probe %RH and temperature. Handle size Ø 26x130 mm, probe Ø
14x215 mm. Connection cable length 2 meters.
HP475ACR
Combined probe %RH and temperature. Connection cable length 2 meters.
Handle Ø 26x110mm. Stainless steel stem Ø 12x560mm. Point Ø 13.5x75mm.
HP475AC1R
Combined probe %RH and temperature. Stainless steel probe Ø 14x480 mm with
sintered stainless steel filter 20μm. Handle 80 mm. Connection cable length 2
meters.
HP477DCR
Combined sword probe %RH and temperature. Connection cable length 2 meters.
Handle Ø 26x110mm. Probe's stem 18x4mm, length 520 mm.
HP478ACR
Combined probe %RH and temperature. Stainless steel probe stem Ø 14x130 mm.
Connection cable length 5 meters.

14.2.3 Wind Speed and Temperature combined probes complete with SICRAM module

HOT-WIRE PROBES
AP471 S1
Hot-wire telescopic probe, measuring range: 0.1...40m/s. Cable length 2 meters.
AP471 S2
Omni directional hot-wire telescopic probe, measuring range: 0.1...5m/s. Cable
length 2 meters.
AP471 S3
Hot-wire telescopic probe with terminal tip for easy position, measuring range:
0.1...40m/s. Cable length 2 meters.
AP471 S4
Omni directional hot-wire telescopic probe with base, measuring range: 0.1...5m/s.
Cable length 2 meters.
VANE PROBES
AP472 S1
Vane probe with thermocouple K, Ø 100 mm. Speed from 0.6 to 25 m/s; temperature
from -25 to 80°C. Cable length 2 meters.
AP472 S2
Vane probe, Ø 60 mm. Measurement range: 0.5...20m/s. Cable length 2 meters.

14.2.4 Photometric/Radiometric probes for Light measurement complete with SICRAM module

LP 471 PHOT Photometric probe for ILLUMINANCE measurement complete with SICRAM
module, spectral response in agreement with standard photopic vision, diffuser
for cosine correction. Measurement range: 0.1 lux...200⋅10
LP 471 LUM 2 Photometric probe for LUMINANCE measurement complete with SICRAM
module, spectral response in agreement with standard photonic vision, vision
angle 2°. Measurement range: 0.1 cd/m
LP 471 PAR
Quantum radiometric probe for the measurement of the photon flow across the
chlorophyll range PAR (Photosynthetically Active Radiation 400 nm...700 nm)
complete with SICRAM, measurement in μmol/m
correction. Measurement range: 0.01μmol/m
LP 471 RAD
Radiometric probe for IRRADIANCE measurement complete with SICRAM
module; in the 400 nm...1050 nm spectral range, diffuser for cosine correction.
Measurement range: 0.1⋅10
HD32.1
2
...2000⋅10
2
s...10μ10
-3
2
W/m
...2000 W/m
- 151 -
3
lux.
3
2
cd/m
.
2
s, diffuser for cosine
3
2
μmol/m
s.
2
.
V2.1