1.7.2

Reset button

The device has a reset button. The reset button is located behind a
screwable IP67 protection cap.
The tightening torque is 4.42 lb-in to 8.85 lb-in (0.5 Nm to 1.0 Nm).
Prerequisite: Keep the working area dry and clean when you are carrying
out a reset.
After pressing the reset button, replace the protection cap. Degrees of
protection IP65/67 are only achieved when the protection cap is closed.
When you press and hold the reset button, you perform the following actions:
1 to 4 seconds
You reset the device to the current configuration.
6 to 9 seconds
You reset the device to the delivery settings.
During this process the user settings are lost. Therefore, before resetting
you must save the current configuration on an external medium.
at least 16 seconds
You have the option of loading a customer-specific configuration saved on
the device as an alternative to the default configuration.
You will find more information in the "Configuration Guidelines User Manual",
in the chapter "Using the Boot Configurations".
Installation BAT450-F