Operating The Device; Connect The Power Supply - Hirschmann BAT450-F User Manual

Industrial access point / client / access bridge
Hide thumbs Also See for BAT450-F:
Table of Contents

Advertisement

The supply voltage is electrically isolated from the housing.
Type and specification of the
supply voltage
Nominal voltage DC
24 V
Voltage range DC incl. maximum
tolerances
16.8 V ... 32 V
Table 3:
Type and specification of the supply voltage
For every supply voltage to be connected, perform the following steps:
 Connect the wires for the supply voltage according to the pin assignment
with a suitable socket.
2.5

Operating the device

Perform the following steps to start up the device:

Connect the power supply

Defining IP parameters
Defining WLAN basic settings
Configuring the transmit power
2.5.1
Connect the power supply
You start up the device by connecting the power supply via the 8-pin, X-
coded M12 socket for PoE port or via a 5-pin, A-coded M12 socket.
 Only connect the device to a PoE network indoors.
 Only run data links indoors (IEEE 802.3 area A).
8-pin, X-coded M12 plug for PoE port
 Connect the data cables according to your requirements.
5-pin M12 plug, A-encoded
 Connect the data cables according to your requirements.
 Plug the socket into the M12 plug on the device.
 Enable the supply voltage.
26
Pin assignment on the device
3
2
5
1
4
2
3
4
5
1
+24 V DC
0V
0V
N.C.
N.C.
Installation BAT450-F
Release 03 08/2016