Figure 3-5 Quick configuration
Step 4 Rotate the knob to select Port 1 Cabinet Qty (number of cabinets loaded by
Ethernet port 1) and set the number of cabinets.
Note:
The number of cabinets loaded by Ethernet port 1, 2, 3, 4 and 5 individually must be
the same. The number of cabinets loaded by Ethernet port 6 must be less than or
equal to that of Ethernet port 1.
The number of cabinets loaded by each Ethernet port must be the integral multiple of
the number of cabinet rows or columns in the LED screen.
Step 5 Rotate the knob to select Data Flow (Front View) and press the knob to select one
data flow according to current cabinet connection.
When setting the data flow, you can view the results of different data flow patterns in
real time on LED display by rotating the knob. When you are satisfied with the LED
display image in which no image parts are overlapped or displayed repeatedly, press
the knob to apply and save the selected data flow. If you press the ESC button, you
will exit current operation and the data flow in preview will not be saved.
Figure 3-6 Data flow

3.4.2 Advanced Configuration

The connection of cabinets loaded by each Ethernet port must follow the 8 data flow
patterns provided in the VX6s.
In advanced configuration, you must manually set the Cabinet Row Qty, Cabinet
Column Qty, Horizontal Offset, Vertical Offset and Data Flow for each Ethernet
port. It is recommended that you use this function under guidance of technical
personnel.
www.novastar.tech