CHAPTER 2. Installing System
2.2 Foundation Work
2.2.1 System Arrangement
A certain distance must be secured around the RRH-2WB in each direction for installation
and maintenance.
Category
Front/Rear
Side
Top/Bottom (In case of Pole Type)
Unit: mm (in.)
System Installation Spaces
The space specifications in the Figure above apply when the pole diameter is
101.6 mm (4 in.). The dimensions may vary depending on the diameter of the
pole.
2-2
Table 2.1 Recommended Distances for System
Tower
Pole[76.3~114.3 (3~4.5)]
390 (15.35)
[Pole Type-1 RRH]
Figure 2.2 RRH-2WB Installation Space
Recommended Distances
800 mm (31.50 in.) or more
200 mm (7.87 in.) or more
1,000 mm (39.37 in.) or more
390 (15.35)
[Tower Type]
720.5 (28.37)
[Pole Type-3 RRH]
Pole[76.3~114.3 (3~4.5)]