Table B.4 Connector Connection Torque Value - Samsung RRH-2WB Installation Manual

Mobile wimax/td-lte
Table of Contents

Advertisement

Ensure that the feeder cable does not interfere with steel towers, ladders and in the
areas chiefly used by people.
Connect the connector to the antenna in a straight line and after connecting, do not
apply excessive force.
Use the vinyl tape for electricity and heat shrink tube for the external exposed part of
the connector not to avoid leak water.
Wind the self-bonding rubber tape overlapping (keep a distance as the half size of
rubber tape) to the connector connection part and wind the vinyl tape for electricity to
the 2 times or more and then cover with the jelly type heat shrink tube.
Connection of Feeder Cable Connector
Connecting the feeder cable connector is critical process, so the qualified workers
who finished the related education should perform.
Connector
SMA connector
TNC connector
N-type connector
Din-type connector
© SAMSUNG Electronics Co., Ltd.
Mobile WiMAX/TD-LTE RRH-2WB Installation Manual/Ver.2.0

Table B.4 Connector Connection Torque Value

Torque Value
2.5 kgf·cm (0.18 lbf·ft)
9 kgf·cm (0.65 lbf·ft)
20 kgf·cm (1.45 lbf·ft)
200 kgf·cm (14.46 lbf·ft)