Figure 12: Sensor - Mounting Options - ELGO Electronic EMIX23 series Operating Manual

Magnetic linear encoder with 0.001 mm resolution
Table of Contents

Advertisement

7.3.2
LED for Distance Monitoring (Option E)
EMIX23 encoders which are equipped with an LED are able to indicate the correct or incorrect reading distance
between sensor and magnetic tape.
LED lights green:
LED lights red:
Please note!
This option is (currently) only available for the version with 5 VDC supply / 5 V-TTL levels.
More information about the reading distance  7.3.1
7.3.3
Mounting Options of the Sensor
Standard (horizontal)

Figure 12: Sensor - Mounting Options

7.3.4
How to install the Sensor and the Magnetic Tape
The location of the reference pulse can be detected by using the magnetic magnifying glass which is included in
the delivery. Please ensure that the mounting is centrally aligned with the magnetic tape center, because the
sensor is wider than the magnetic tape. When ordering, the reference pulse position is starting from the right
side of the magnetic tape.
N S N
N S N S N S N S N S
Reference mark
Figure 13: Installing Sensor and Tape
The example image above shows:
Sensor: EMIX23-000-05.0-0001-00-E-R
Magnetic tape: MB20-20-10-2-R-C-REF148
 Reading distance is ok
 Reading distance is not ok
148,00
N
S N S N S N S N S N S N S N
Sensor
Reference sensor
- 19 -
Option L (vertical)
Error LED
Fine interpolation track
Installation and First Start-Up

Advertisement

Table of Contents
loading

Table of Contents