Mounting Of The Sensor - ELGO Electronic EMIX23 series Operating Manual

Magnetic linear encoder with 0.001 mm resolution
Table of Contents

Advertisement

7.3

Mounting of the Sensor

Two M3 screws to be used to install the sensor head.
The specified tolerances must be adhered to.
7.3.1
Tolerances EMIX23
Table 2: Tolerances EMIX23
Tolerances
Distance between sensor and tape
Pitch
Roll
Yaw
Lateral offset with standard magnetic tape
Lateral offset with option REF (magnetic tape)
±0,5°
Figure 11: Sensor Tolerances
Sensor distance
Pitch
Yaw
max. 0.8 mm
The maximum allowed distance of 0.8 mm may not
be exceeded at any position
The maximum allowed distance of 0.8 mm may not
be exceeded at any position
<± 0,5°
± 2.5 mm
± 0.5 mm
±2.5 mm* (standard)
±0.5 mm* (option REF)
*) Related to the system accuracy (see
Technical Data) and 10 mm wide tape
- 18 -
Installation and First Start-Up
Roll
Lateral offset

Advertisement

Table of Contents
loading

Table of Contents