System Setup Screen Item Descriptions (Continued)
Auto Power Limiting Enable
Circuit Test State 4 Power
Level
Bake Out Enable
Force Bake Out Enable
Bake Out Alert Enable
Bake Out Limit
Bake Out Power
Bake Out Time Per Cycle
Number of Bake Out Cycles
Bake Out Setpoint
At Bake Out Temperature
Window
Heat to Bake Out Setpoint
Timeout
Page 110
v 1.0 — August 2018
Item
If checked, the Auto Power Limiting feature is enabled.
Determines the power percentage applied during circuit test state
4.
If this parameter is enabled, the system will run the bake out test
and apply a low voltage to remove the moisture in a heater if
required. Toggle this parameter on or off.
Toggle this parameter on or off. If this parameter is on, each zone
in the system is baked out upon startup.
If this parameter is enabled, the system stops and generates an
alarm for each zone with a bake-out condition that has not been
cleared during the bake out cycle.
If this parameter is disabled, the system exits the existing bake-out
cycle and continues the startup sequence.
The system uses this value to assess whether a bake-out condition
exists. Upon system startup, if any zone exceeds this limit, the
system will enter bake-out mode.
For ICC
value is 0.2 amps.
For ICC
default value is 200 milliamps.
The system uses this value during the bake out process.
The parameter range is 0 to 25%. The default value is 5%.
Length of the bake out cycle. The parameter range is 1 to 30
minutes. The default value is 5 minutes.
The number of attempts to bake out the moisture in a heater. The
parameter range is 1 to 10. The default value is 1.
Specifies the bake out setpoint the zones must achieve during the
bake out process. The default value is 100°C (212°F). Displays only
3
if ICC
During the bake out process, this parameter specifies the
threshold that all zones must achieve before the bake out cycle
value starts counting down. The default value is 5°C (9°F). Displays
only if ICC
Specifies the amount of time the zones are given to achieve the
bake out setpoint. If the time period expires, a warning message
displays the problem and what happens when the warning
message is acknowledged. Displays only if ICC
Description
2
cards, the parameter range is 0 to 5 amps. The default
3
cards, the parameter range is 1 to 999 milliamps. The
cards are installed.
3
cards are installed.
Altanium Neo5
3
cards are installed.