8.3.1

Automatic Thermocouple Wiring

Thermocouples can be inadvertently cross-wired in the mold, where the thermocouple for
one heater becomes connected with another heater, and vice versa.
The Neo5 wiring test checks the thermocouple/heater wiring and determines whether the
wiring is correct. When the test is complete and if an error was found, the zone with the error
will display Failed, followed by the zone number with the maximum response in the wiring
column. Also, the Re-Wire button in the Mold Test, Settings screen will be enabled.
To automatically rewire thermocouples:
1.
2.
Page 96
Item
The ground fault test tests for an earth leakage in each zone. Earth
leakage values are displayed as follows:
The bake out test tests for moisture in each heater. Bake out values are
displayed as follows:
The measured earth leakage in amps.
Time taken to test each zone.
"Not tested", could be because the zone was not selected, or because one or two test
types (heaters, sensors, or wiring) were not checked. "Test did not complete", means
the test timed out or the user stopped the test.
If necessary, on the bottom of the Mold Test screen, touch
On the Settings screen, touch the Rewire button
automatically reassign the mold thermocouples to their correct zones.
NOTE:
This information is saved with the current mold setup.
v 1.0 — August 2018
? = Test did not complete.
- - - = No current sensor for this zone.
OK = Passed.
Fail = Failed (measured a leakage value that exceeded the Earth
Leakage Limit setting in Quick Set).
? = Test did not complete.
- - - = No current sensor for this zone.
OK = Passed.
Fail = Failed (measured a leakage value that exceeded the Bake Out
Limit setting in the System Setup screen).
? = Test did not complete.