5 Installation Procedure
u
Wire Gauges, Tightening Torques, and Crimp Terminals
Wire Gauges and Tightening Torques
n
Wire gauge and torque specifications are listed in
Terminal
Screw
Signal
Size
A+, A–, B+,
B–, Z+, Z–,
FE, IP, IG
M2
AO, IG, BO,
IG, ZO, IG
Crimp Terminals
n
Yaskawa recommends using CRIMPFOX 6 by Phoenix Contact or equivalent crimp
terminals with the specifications listed in
Note: Properly trim wire ends so loose wire ends do not extend from the crimp terminals.
6 mm
d2
d1
L
32
Table 5 Wire Gauges and Tightening Torques
Tightening
Torque
Recomm.
Nm
Gauge
(inlb)
mm
2
0.22 to 0.25
0.75
(1.95 to 2.21)
(18 AWG)
Table 6
Wire Gauge
Phoenix Contact
mm
2
0.25 (24 AWG)
0.34 (22 AWG)
0.5 (20 AWG)
YASKAWA ELECTRIC TOBP C730600 75B YASKAWA AC Drive Option PG-B3 Installation Manual
Table
5.
Bare Cable
Applicable
Gauges
mm
2
Stranded wire:
0.25 to 1.0
(24 to 17 AWG)
Solid wire:
0.25 to 1.5
(24 to 16 AWG)
Table 6
for wiring to ensure proper connections.
Crimp Terminal Sizes
Model
AI 0.25 - 6YE
10.5 (13/32)
AI 0.34 - 6TQ
10.5 (13/32)
AI 0.5 - 6WH
Crimp Terminals
Applicable
Recomm.
Gauges
Gauge
mm
2
mm
0.5
0.25 to 0.5
(20 AWG)
(24 to 20 AWG)
L
d1
mm (in)
mm (in)
0.8 (1/32)
0.8 (1/32)
14 (9/16)
1.1 (3/64)
Wire
Type
2
Shielded
twisted
pair, etc.
Shielded
cable, etc.
d2
mm (in)
2 (5/64)
2 (5/64)
2.5 (3/32)