2. Adjustable Maximum Temperature Setting

The Mira Extreme is fully performance tested and the maximum temperature has been
set under ideal installation conditions at the factory. The temperature stop is set to 41°C
and depressing the override will increase the temperature by 5°C to approximately
46°C. Site conditions and personal preference may make it necessary to reset these
temperatures.
Note! An adequate supply of hot water at least 12°C above the required
temperature must be available for correct operation of the shower control.
Warning! Resetting the temperature of the temperature stop will also reset the
maximum temperature obtainable with the override operated.
2.1.
Turn the temperature control knob
anticlockwise to the maximum
temperature stop. Do not depress
the override button.
2.2.
Insert the end of the push-fit tool
under the temperature control
knob, inline with the temperature
override button, and lever off the
temperature knob.
2.3.
Press the upper flow control button
to start the flow of water, allow the
water temperature to stabilise.
Turn the
temperature
control to the
maximum
temperature
stop.
Temperature
Control Knob
Push-fit
Release
Tool
23