Mira Extreme Thermostatic Installation & User Manual page 33

Power shower
Hide thumbs Also See for Extreme Thermostatic:
Table of Contents

Advertisement

5. Inlet Manifold, Check Valve – Removal and Installation
The following procedure can be applied for cleaning or renewing the inlet manifold, inlet
check valves or 'O' seals.
Warning! Before proceeding turn off the electrical and water supplies. The electricity
supply must be turned off at the mains and , if applicable, the appropriate circuit fuse
removed. Mains electrical connections are exposed when the cover is removed.
5.1.
Remove the front cover as detailed in "Front Cover – Removal and
Installation".
5.2.
Disconnect the electrical supply
cable from the terminal block.
5.3.
Remove the flexible hose from the
appliance.
5.4.
Remove the three wall fixing
screws.
5.5.
Using the push-fit release tool,
push back and hold the collets
from the supply pipework, lift the
Mira Extreme from the wall to
remove the supply pipework from
the inlet manifold.