Mira Extreme Thermostatic Installation & User Manual page 29

Power shower
Hide thumbs Also See for Extreme Thermostatic:
Table of Contents

Advertisement

Malfunction
Flow of water virtu-
ally
stops
and
surges on/off, after
a few minutes.
Shower runs cold
after 5–10 minutes.
Shower temperature
affected by use of
adjacent hot/cold
tap.
Maximum shower
temperature too hot.
Shower temperature
too cold.
Blend temperature
unstable.
Cause
Insufficient storage of
cold water in cistern
(230 litres recom-
mended).
Insufficient storage of
hot water in cylinder.
Insufficiently sized
pipework for both sys-
tems to be used to-
gether.
Incorrect setting of
maximum tempera-
ture.
Maximum temperature
incorrectly set.
Hot water cylinder tem-
perature less than 12°C
above shower tem-
perature.
Inlet filter blocked.
Isolating valve partially
closed.
Spray plate blocked.
Remedy
Increase storage of cold water cis-
tern.
Increase storage of hot water.
Increase pipe sizes or separately
feed shower. Refer to plumbing sys-
tem diagrams in the section "Instal-
lation Requirements".
Reset maximum temperature. Re-
fer to "Commissioning: Adjust-
able Maximum Temperature
Setting".
Reset maximum temperature. Re-
fer to "Commissioning: Adjust-
able Maximum Temperature
Setting".
Adjust cylinder temperature.
Note! It is recommended that the
stored water temperature does not
exceed 65°C.
Clean filters.
Open valve.
Clean spray plate. Refer to the
Installation and User guide sup-
plied with the shower fittings.