Warning! This Mira Extreme
must be fixed to the wall at all
three fixing points. The fixing holes
are elongated to assist in vertical
and horizontal alignment.
3.14. Screw the Mira Extreme to the
wall using either the supplied wall
screws or alternative fixings
depending on the wall structure.
Do not over-tighten!
Ensure that the electrical supply
cable is correctly seated in the
channel in the back of the case.
3.15. Connect the live, neutral and earth
conductors of the electrical supply
cable to the terminal block. The
supply cable earth connector
should be sleeved.
3.16. To refit the cover, replace the
cover electrical connection on the
PCB by gripping the sides of the
connector between two fingers and
easing the connector into position
by moving from side to side.
Note! Two lugs on the top of the
connector are provided to ensure
the correct orientation (see
illustration).
3.17. Position the cover and secure
with the three cover retaining
screws.
Do not over-tighten!
20
Orientation Lugs