Allen-Bradley PowerFlex 700AFE Migration Manual page 36

Regenerative bus supply
Hide thumbs Also See for PowerFlex 700AFE:
Table of Contents

Advertisement

Chapter 1
Selection Considerations
36
Table 10 - Enclosure Features (Continued)
Description
PowerFlex 700AFE Bus Supply
Cat No. 20Y...
IP54, NEMA/UL Type 12
Dimensions (H x D), approx.
(width varies)
Dimensions exclude fan
housings, handles and so on.
AC Input Cable Entry
• (s), IP21 Rittal, bottom only
• (s), IP20 2500 MCC, top only
DC Power Bus
• Not applicable, IP21 Rittal,
• (s), IP20 2500 MCC, Centerline
Control Power Bus
Table 11 - Environmental Features
Description
PowerFlex 700AFE Bus Supply
Cat No. 20Y...
Environmental Compliance
Refer to Rockwell Automation website:
http://www.rockwellautomation.com/global/about-us/sustainability-ethics/
product-environmental-compliance.page?
Altitude (without derate)
1000 m (3000 ft)
See publication
detailed derating information.
Ambient Temperature Range
• 0...40 °C (32...104 °F)
(without derate)
• 0...35 °C (32...95 °F) Frame 13
See publication
detailed derating information.
Storage Temperature
-40...+60 °C (-40...+140 °F)
Relative Humidity
5...95%
(noncondensing)
Mechanical Shock
Non-operational;
• 15G peak for 11 ms duration,
Operating; not applicable
Rockwell Automation Publication 750-RM003A-EN-P - April 2018
PowerFlex 755TM Bus Supply
Cat. No. 20J...
Rittal
2000 x 600 mm (78.7 x 23.6 in.)
See publication
publication
dimensional data.
• (s) Bottom all frames
• (s) Top frames 8...9, specify power
• (o) Top, frames 10...12, specify power
• (s) frames 8...10, 3000 A DC
connection terminals, near top/
• (s) frames 11...12, 4700 A DC
front, side exit
• (o) frames 8...10, 4700 A DC specify
horizontal bus bars, side exit,
• Near top/back, horizontal bus bars, side
frame 10 1250 A DC,
frame 13 3000 A DC
• (s) 240V AC, 1 PH, 100 A rms
• (s) 24V DC, Auxiliary Control Bus,
• (s) 120/240V AC, 1 PH, User Control Bus,
• Control Bus Connector taps are rated
PowerFlex 755TM Bus Supply
Cat. No. 20J...
1000 m (3000 ft)
20Y-UM001
for
See publication
derating information.
• -20...+40 °C (-4...+104 °F), all
600/690V AC
See publication
20Y-UM001
for
derating information.
-40...+70 °C (-40...+158 °F)
5...95%
Packed for shipment;
• Meets ATSM International standards
EN50178/EN60068-2-27
Operating (packaged products);
• 10G peak for 11 ms duration (+/-1 ms),
750-TD101
and
750-IN101
for detailed
option (-P17) w/o wiring bay
option (-P16) w/ wiring bay
power option code (-P46)
exit
100 ADC
100A rms
10 A per pole.
750-TD100
for detailed
frame ratings and enclosure types
750-TD100
for detailed
three shocks in each direction in each
axis. See the Shock Events information
in the Technical Data, publication
750-
TD100
for detailed information about
the maximum number of shock events.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerflex 755tm

Table of Contents