Allen-Bradley PowerFlex 700AFE Migration Manual page 31

Regenerative bus supply
Hide thumbs Also See for PowerFlex 700AFE:
Table of Contents

Advertisement

Figure 5 - PowerFlex 755T Control Bus Configuration (External 240V AC Control Power
Connector)
Table 5 - Standard and Optional Control Power Comparison
Description
240V AC Primary Control Power (s) Control transformer,
24V DC Auxiliary Control Power —
120/240V AC User Control
Power
Table 6 - PowerFlex 755TM Bus Supply External 240V AC Control Power Requirements
Bus Supply
Required (A rms)
Frame
IP21
Enclosure
8
8.4
9
11.2
10
17.5
11
20.3
12
26.0
Rockwell Automation Publication 750-RM003A-EN-P - April 2018
PowerFlex 700AFE
PowerFlex 755TM Bus Supply
(s) Primary 240V AC control bus bars, 100 A, powered
240V AC,1 PH
from user supplied 240V AC, 50/60Hz, 1 PH, neutral
grounded protected primary control power. See
Table 6 on page 31
240V AC power requirements.
(o) Control transformer, specify control option code
(-C1), 240V AC, 1 PH will supply power to primary
control bus bars. see
Comparison on page 33
supply for additional 240V AC power available with the
(–C1) option installed.
• The PowerFlex 755T packaged product uses the
primary 240V AC control bus bars to supply 240V AC
1 PH control power to various circuits. Primary
control power is required and must be supplied by
the user or from the optional control transformer.
(s) Auxiliary 24V DC bus bars, 100 A.
• User supplied 24V DC control power.
see
Specification and Feature Comparison on
page 33
for PowerFlex 755TM bus supply 24V DC
power requirements.
• The PowerFlex 755T packaged product uses these
bus bars to supply 24V DC auxiliary power to
various circuits when the 240V AC primary control
power is shut off.
(s) User 120/240V AC control bus bars, 100 A.
• User supplied 120V AC or 240V AC 1 PH control
power.
• The User 120/240V AC control power and bus bars
are not used by PowerFlex 755T product.
Required for Optional Wiring Bays (A rms)
IP54
Entry
Enclosure
(Power Opt Code -P16)
10.4
0.39
15.2
0.39
23.5
0.39
28.3
0.39
36.0
0.39
Selection Considerations
Chapter 1
for PowerFlex 755TM bus supply
Specification and Feature
for PowerFlex 755TM bus
Exit
(Power Opt Code -P15)
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerflex 755tm

Table of Contents