PROPORTIONING TEST

L
1. Turn the three way-valve to the TA index.
2. Remove the static mixer to install, instead of it, the adapter fitting (marked TB, F 3/4 JIC
- F 1/4 G).
3. Place 2 beakers under the fluid outlets : TA and at the outlet of the TB mixer block.
4. Go in the menu F3 an then access to the parameter 10 (without catalyst flushing) or
parameter 11 (with catalyst flushing) to activate the proportioning test.
5. When you have a sufficient sample volume, activate ESC.
Note : During the proportioning test, the error 6 is desactivated. The other errors are active only if
the flow-switch is activated. We advice you to keep the error 6 active (P11 / P12 >0).
After that operation, you must carry out a flushing to clean the 3 way-valve.
During the flushing, flush correctly the TA side of the valve, then turn the 3 way-
valve to IN to flush the fitting at the outlet of the injector.
Once the test ended and the flushing carried out, install the mixer and leave the 3
way-valve on IN.

11. FLUSHING (F2)

The menu is useful for the flushing. When you want to flush the CYCLOMIX
when you are on the F-2 menu.
For the CYCLOMIX
The CYCLOMIX
After confirming via
volume and the buzzer sounds continuously. When you begin the flow, the buzzer sounds
intermittently and a breakdown begins on the display unit :
When the breakdown has reached 0, the CYCLOMIX
BASE flushing has ended.
For a long duration shutdown without CATA flushing, flush the catalyst circuit :
You must disconnect the CATA hose and connect, instead of it, the SOLVENT hose (CATA). Pilot
with air the VP6 valve until the solvent flows clean.
SAMES KREMLIN
To carry out a mixing test, decrease a lot the pressure of the fluids
(maximum 18 bar / 261 psi) to provide any projection of dangerous
material. We advice you to wear protective glasses and gloves.
K
TM
MICRO without CATA flushing :
TM
MICRO asks for a confirmation to start flushing :
,
TM
the CYCLOMIX
Page 24
MICRO opens the solvent valve, starts the counting of the
TM
MICRO closes the solvent valve and the
TM
MICRO, activate
Manual : 573.191.112

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cyclomix micro+Cyclomix micro+ ph

Table of Contents