16. DISASSEMBLY - REASSEMBLY

Stop the CYCLOMIX
Depressurize the systems.
Guards (air motor cover, coupling shields, connectors,...) have been designed for
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards.

MIXER

Unscrew the mixer assembly and replace it with a new one.

FLOWMETER

The flowmeters consist of an electronic sensor
(1) and of a mechanical part that is composed
of bearings and gearings.
To remove the flowmeter : disconnect the
connector (2) and unscrew the sensor (1).
Then loosen the screws (3) of the mechanic
part. Once the screws removed, open the
flowmeter paying attention to the seal (4) and
to the gearings (5). Clean the different
elements then reinstall.
SAMES KREMLIN
TM
MICRO after its flushing.
safe use of the equipment.