3. OPERATING PRINCIPLE

The 2 BASE and CATALYST materials are sent to the mixing system from 2 pumps or pressure tanks.
The base crosses a piloted valve (A1) and a meter (CA), the catalyst is directly sent to the meter (CB).
The cycle begins with the opening of the BASE valve (A1). The 2 meters send their informations to the
computer that shuts off the catalyst valve (VP6) when the computerized mixing ratio is reached.
The mixing process is based on a base constant flow. The catalyst flow is injected low under high
frequency. The injection is made directly into the base flux at the mixer level.
The automaton checks continuously the mixing ratio and if it notices a fault that it cannot correct, an
alarm is activated. The CYCLOMIX
vp6
CB
TA
MEL
A1
Base piloted valve (A)
SA
Base solvent piloted valve(SA)
A2
Base piloted valve (depending upon version)
A3
Base piloted valve (depending upon version)
B
Catalyst piloted valve (depending upon
version)
SB
Cata solvent piloted valve (depending upon
version)
SAMES KREMLIN
TM
MICRO goes on safety mode.
B1
AR2
CA
AR1
IN
Page 7
B
SB
SB
A1
A2
IN
Three way-valve to mixer
TA
Sampling outlet for the base
CA
Base meter
CB
Cata meter
VP6
Injection piloted valve
MEL
Mixer
A
SA
SA
A3
A
A