Installation; Description Of The Label Markings - SAMES KREMLIN Cyclomix Micro User Manual

Electronic mixing system
Table of Contents

Advertisement

NOTA : The version 2.82 is only compatible on electronic boards with version higher than V.2.32. Here
after an overview of major versions :
Kinf of
Manufacturing
processor
date first units
- Electronic
card
PIC 18F4520
PIC 18F4620
Different versions of the CYCLOMIX
Configurations
TM
CYCLOMIX
MICRO
TM
CYCLOMIX
MICRO +
TM
CYCLOMIX
MICRO+ PH
The control unit is the same for all the versions of the CYCLOMIX
You can change the configuration displacing the shunt located on the µ card (J7 terminal)
- (refer to"Annexes" - electric diagram).

5. INSTALLATION

DESCRIPTION OF THE LABEL MARKINGS

TM
The CYCLOMIX
MICRO is fitted with 2 label markings : a label marking on the control unit and the other one
on the fluid module.
Marking label on the control unit
(bay located outside the spray booth in a safe area)
SAMES KREMLIN
Soft
version
-
2.31
09 Y 1001
2.32
10 Y 1133
2.6
14 Y 1152
2.82
TM
MICRO :
BASE
1 base + 1 solvent
3 bases + 1 solvent
1 base + 1 solvent
3 bases + 1 solvent
1 base + 1 solvent
3 bases + 1 solvent
Page 9
Presence of error 6
-
-
Yes
Yes
- Can be setup with P12
CATALYST
1 cata
1 cata
1 cata + 1 solvent
1 cata + 1 solvent
1 cata + 1 solvent
1 cata + 1 solvent
TM
MICRO.
Marking label on the fluid module
(fluid module located outside the spray booth in a
safe area)
Soft compatibility
with 2.82 latest
version
-
Yes
Yes
Yes
Manual : 573.191.112

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cyclomix micro+Cyclomix micro+ ph

Table of Contents