One of the meters does not count
AUTO-WASH
You cannot switch to production with the auto-wash : it only can be used as a support.
SAMES KREMLIN
FAULTS
Page 35
CHECKING
TM
If the CYCLOMIX
MICRO indicates that the BASE
flowmeter is blocked and that the fault is recurrent :
- Clean the mobile parts of the flowmeter (gearing
and bearings),
- Check the sensor assembly,
- Check the electric wiring of the sensor.
TM
If the CYCLOMIX
MICRO indicates that the
CATALYST flowmeter is blocked and that the fault is
recurrent :
- Clean the mobile parts of the flowmeter (gearing
and bearings),
- Check the sensor assembly,
- Check the electric wiring of the sensor,
- Check the VP6 valve,
- Check the piloting electrovalve of the VP6 valve,
- Check if there is a clogging of the injector.