Assemble filters at the outlet of the BASE and CATA pumps.
Assemble pressure regulators at the outlet of the BASE and CATA pumps.
Install the fluid and air hoses between the pumps and the CYCLOMIX
TM
CYCLOMIX
MICRO and the gun. When choosing the fluid hoses, comply with the pressures delivered
by the pumps. For the air hoses, install non-static hoses.
Unscrew the regulators before supplying air to the installation.
Check that the three way-valve is in the IN fluid circuit sense and not in the TA circuit sense.
Nota : To connect the SOLVENT pump (CATA) to the CYCLOMIX MICRO :
-
choose a CYCLOMIX
-
or disconnect the CATA hose at non-return valve level (CATA) of the equipment and replace it
connecting the SOLVENT hose (CATA).

6. OPERATING

DRIVING FROM THE CYCLOMIX

SCREEN
The different menus and the informations relating to the CYCLOMIX
alphanumeric screen.
KEYBOARD
ESC
The keyboard is used thanks to a magnet provided with the CYCLOMIX
enables to drive the CYCLOMIX
That technology enables the operator to save time and to carry out his work from the application place.

SWITCHING ON THE CYCLOMIX

The placing of the system into operation requires that the BASE, CATALYST and
SOLVENT drums are full enough to ensure the production.
Connect the gun before placing the system into operation.
Supply air to the CYCLOMIX
Supply air to the air regulators of the pumps (BASE, CATALYST, SOLVENT).
Switch on the control unit (switch located on the side of the unit).
When switching on the control unit, a menu is displayed on the screen.
Nota : Parameters have been programmed in the factory before the delivery of the CYCLOMIX
You must adapt the parameters to the use. They must be modified by an authorized person (refer to list
of parameters).
SAMES KREMLIN
TM
MICRO set up with 1 catalyst and one cata solvent,
TM
MICRO
That key enables to quit the menus or the different modes (production, flushing,
parameters).
That key enables to enter in the different menus or to validate a value of parameter.
That key enables to shift from a menu to another and to increase the value of a
parameter during modifications of value.
That key enables to shift from a menu to another and to decrease the value of a
parameter during modifications of value.
TM
MICRO inside the booth if the box is installed behind the booth glass.
TM
MICRO
TM
MICRO (minimum 4 bar / 58 psi).