Omron V700 Series Operation Manual page 53

Electromagnetic inductive rfid system
Hide thumbs Also See for V700 Series:
Table of Contents

Advertisement

Controller
Wiring RESET Signal
I/O Solderless Terminal
Wiring SYNC Signal
The I/O terminals use M3 set screws. The following type of solderless terminal
can be connected to these terminals
Tighten each screw to a torque of approximately 6 kgf • cm.
Note
1. Make sure that the input voltage does not exceed a maximum permissible
input voltage of 26.4 V, otherwise the Controller may malfunction.
2. Separate power lines and high-tension lines from the input line in order to
protect the input line from noise interference.
Another Controller
• Connect the SYNC signals of other Controllers operating in synchronization.
RESET
24 VDC
input
6.5 max.
M3
Shielded wire
+
Section
4-1
Another Controller
+
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

V700-h02V700-cd1dV700-d23p31V700-h01V700-d13p21

Table of Contents