Omron V700 Series Operation Manual page 112

Electromagnetic inductive rfid system
Hide thumbs Also See for V700 Series:
Table of Contents

Advertisement

Maintenance and Inspection
Inspection Items
Item
Supply voltage fluctuation
Environment
(1) Ambient temperature
(2) Ambient humidity
(3) Vibration and shock
(4) Dust
(5) Corrosive gas
Panel condition
(1) Ventilation
(2) Packing for any
enclosed construction
I/O power supply
(1) Voltage fluctuation
(2) Ripple
Mounting condition
Error logging
100
Detail
Check that the supply voltage
fluctuation at the power supply
terminal block is within the
permissible range.
Check that there is no frequent
instantaneous power failures or
radical voltage drops.
(1) and (2) Check that the
ambient temperature
and humidity are
within the specified
ranges.
(3) Check that no vibration or
shock is transmitted from any
machines.
(4) Check that the system is free
of dust accumulation.
(5) Check that no metal part of
the system is discolored or
corroded.
(1) Check that the system is
ventilated properly with natural
ventilation, forced ventilation,
or cooling air.
(2) Check that the packing is
properly attached with no
damage.
Check on the I/O terminal block
that the voltage fluctuation and
ripple are within the permissible
ranges.
Check that each device is securely
mounted.
Check that each connector is
securely connected.
Check that no screw of the
terminal block is loosened.
Check that no wire is broken or
nearly broken.
Check that the distance between
the ID Tag and Antenna is within
the specified range.
Check that the GR terminal is
grounded.
Check the details of error logs.
Criteria
Supply voltage rating
Within permissible voltage
fluctuation range
(1), (2) and (3)
Check that the ambient
temperature and humidity are
within the specified ranges.
(4) The ambient temperature,
humidity, vibration, and shock
must be within the specified
ranges.
(5) The system must be free of
dust accumulation.
No metal part of the system is
discolored or corroded.
(1) The interior temperature must
be within a range between
–10°C and 55°C with proper
ventilation.
(2) The packing has no damage.
The voltage fluctuation and ripple
must be within the permissible
ranges.
There must be no loose screws.
Each connector is locked or
securely tightened with screws
There must be no loose screws.
There must be no wire that is
broken or nearly broken.
The distance between the ID Tag
and Antenna must be within the
specified range.
The terminal must be grounded to
a resistance of 100 Ω or less.
---
Section
7-5
Remarks
Multimeter
Power supply
analyzer
Maximum and
minimum
thermometer
Hygrometer
---
Multimeter
Oscilloscope
---
---
---
---
---
---
---

Advertisement

Table of Contents
loading

This manual is also suitable for:

V700-h02V700-cd1dV700-d23p31V700-h01V700-d13p21

Table of Contents