Omron V700 Series Operation Manual page 43

Electromagnetic inductive rfid system
Hide thumbs Also See for V700 Series:
Table of Contents

Advertisement

Controller
Settings
Node Number Settings
Default Set Values
SW3 (left)
SW4 (right)
Use the provided screwdriver to make switch settings as shown below.
The following table shows default set values.
SW1
Node number (10's digit)
SW2
Node number (1's digit)
SW3-1
System reserved pin
Communications sync
SW3-2
setting
i
SW3-3
SW3-4
SW3-5
Low power consumption
setting
SW3-6
Communications distance
setting
SW3-7
Not used
SW3-8
Termination resistance
setting
Baud rate setting
SW4-1
SW4-2
SW4-3
Data length setting
Parity bit setting
y
SW4-4
SW4-5
SW4-6
Stop bit length setting
SW4-7
Communications mode
setting
SW4-8
Time-out setting
Note The pin 8 setting of SW4 will be meaningless if pin 7 is set to OFF.
DIP Switch Settings
Name
Default set
value
0
0
OFF
y
OFF
OFF
OFF
OFF
OFF
OFF
OFF
g
OFF
OFF
OFF
g
OFF
OFF
OFF
OFF
OFF
Section
4-1
Meaning
Node number 00
Not used
No sync
y
Normal mode
Long-distance mode
Not used
No
9,600 bps
,
p
7 (ASCII7)
Even
2
No ACK/NACK control
See note. (500 ms)
29