Hameg HM8118 Manual page 37

Programmable lcr-bridge
Hide thumbs Also See for HM8118:
Table of Contents

Advertisement

Available languages

Available languages

47
46
TRIG / UNIT (Pushbutton)
27
Triggers a measurement in the manual trigger mode; se-
lection of a unit
AUTO / 6 (Pushbutton)
28
Selection of the automatic measurement function; numeric
key 6 when entering numeric parameters
M / – (Pushbutton)
29
Selection of the measurement function „Mutual Inductance"
(only with the appropriate cable set) or input of the character
„-".
R-Q / 5 (Pushbutton)
30
Selection of the measurement function 'Resistance' R und
'Quality factor' Q; numeric key 5 when entering numeric
parameters
Θ
N-
/ . (Pushbutton)
31
Selection of the measurement function 'Turns ratio' N and
Θ;
'Phase angle'
input of the character ". " when entering
parameters
C-R / 4 (Pushbutton)
32
Selection of the measurement function 'Capacitance' C
and 'Resistance' R; numeric key 4 when entering numeric
parameters
G-B / 0 (Pushbutton)
33
Selection of the measurement function 'Conductance' G
and 'Susceptance' B; numeric key 0 when entering numeric
parameters
C-D / 3 (Pushbutton)
34
Selection of the measurement function 'Capacitance' C and
'Dissipation factor' D; numeric key 3 when entering numeric
parameters
R-X / 9 (Pushbutton)
35
Selection of the measurement function 'Resistance' R and
'Reactance' X; numeric key 9 when entering numeric para-
meters
L-R / 2 (Pushbutton)
36
Selection of the measurement function 'Inductance' L and
'Resistance' R; numeric key 2 when entering numeric pa-
rameters
Θ
Y-
/ 8 (Pushbutton)
37
Selection of the measurement function 'Admittance' Y and
Θ
'Phase angle'
; numeric key 8 when entering numeric
parameters
48
45
44
C o n t r o l s a n d d i s p l a y
L-Q / 1 (Pushbutton)
38
Selection of the measurement function 'Inductance' and
'Quality factor' Q; numeric key 1 when entering numeric
parameters
Θ
Z-
/ 7 (Pushbutton)
39
Selection of the measurement function 'Impedance' Z and
Θ
'Phase angle'
; numeric key 7 when entering numeric
parameters
DISPLAY MODE (Pushbutton)
40
Toggles the display: measurement value with / without
parameters
RECALL / STORE (Pushbutton)
41
Save and recall of instrument configurations (10 memories)
REMOTE / LOCAL (Pushbutton)
42
Toggling between front panel and external operation; the
REMOTE/LOCAL pushbutton lights up if the instrument is
being addressed via the interface
order to return to local control push REMOTE/LOCAL, pro-
vided the local control was not locked out via the interface
(local lockout). If local lockout was activated, the instrument
can not be operated from the front panel.
Ground (4 mm socket)
43
Ground connector ( ). The socket is directly connected to
the mains safety ground!
Rear panel
TRIG. INPUT (BNC socket)
44
Trigger input for external triggering
BIAS FUSE (Fuse holder)
45
Fuse for external voltage input ext. BIAS
ext. BIAS (4 mm safety sockets) External bias input (+, –)
46
INTERFACE
47
HO820 Dual Interface USB/RS-232 (galvanically isolated) is
provided as standard
HANDLER INTERFACE (25 pin D-Sub socket)
48
Output to control external binning sorters for components
(option HO118)
POWER INPUT (Power Cord Receptacle)
49
49
(Remote Control). In
47
Subject to change without notice
37