Main Operator's Panel Control Descriptions

The following is a list of each control on the operator's panel and a description of the functions performed at
each setting.
HEATER
Fig. 3-3. Heaters Illuminated Pushbutton
RUN
Fig. 3-4. Run/Safe/Pendant Key Switch
Fig. 3-5. Reset Pushbutton
C9999- -2 Issue 1
SAFE
MAINT
RESET
3.2.3.1
ROLLER HEAT ON / OFF - -
ON -- When pushed, the button illuminates,
indicating upper and lower heaters are turned ON.
OFF -- When pushed again, the heaters are turned
OFF.
Approximate warm up time for heaters is between
25--30 minutes.
3.2.3.2
SAFE / RUN / MAINT - - Key Switch
RUN -- The machine drive cycles continuously.
This is the normal switch position for production.
If conditions are safe, pushing RESET will allow
the machine to operate.
SAFE -- No machine cycle is possible.
MAINT (Maintenance) -- When the keyswitch is in
this position, the machine can only be indexed at a
slower speed. The safety doors and guards
(except for the tabcutter guard) can be removed to
perform maintenance and adjustments. If the rear
machine guard is removed, the rollers will not heat.
Always press the RESET button after changing the
switch from RUN to MAINT or visa versa.
3.2.3.3
RESET - - Blue Pushbutton
Resets machine, and verifies it is safe to run after
an emergency stop.
Press this button when changing the
RUN/SAFE/MAINT switch from SAFE position to
RUN.