4 Maintenance
Fig. 4-88. Calibrating Fiber Optics
Fig. 4-89. Remove Rear Pile Feeder Cover and
Amplifier Cover
4- -56
4.2.30.2 Calibrating Fiber Optics
The fiber optic amplifier is preset at the factory and
should not require too much adjustment but due to
variations in index stocks, the amplifier may have
to be slighty recalibrated.
If the sensitivity is set too strong, it may read right
through certain paper stocks. If it is set too weak, it
will not read the paper stock at all.
Note !
Do not attempt adjustments to the Fiber
Optic Amplifier unless you are familiar
with performing this type of
adjustment.
To adjust the Fiber Optic Amplifier
Step: 1. E--Stop the machine.
Step: 2. Remove the air lines and right side pile
feeder cover.
Step: 3. Remove the cover of the amplifier box.
C9999- -2 Issue 1