GB
5.2

Fault code descriptions

The fault codes that the user can correct themselves are given below. If a different
code appears, call a service technician.
Fault
Description
code
E 6
High temperature
The thermal overload cut--out has tripped.
The current welding process is stopped and cannot be restarted until the temperature has
fallen.
Action: Check that the cooling air inlets or outlets are not blocked or clogged with dirt.
Check the duty cycle being used, to make sure that the equipment is not being overloaded.
E 14
Communication error (bus off)
Serious interference on the CAN bus.
Action: Check that there are no faulty units connected on the CAN bus. Check the cables.
Send for a service technician if the fault persists.
E 16
High open- -circuit voltage
Open circuit voltage has been too high.
Action: Turn off the mains power supply to reset the unit. Send for a service technician if
the fault persists.
E 19
Memory error
Content of existing memory is incorrect. Basic data will be used.
Action: Turn off the mains power supply to reset the unit. Send for a service technician if
the fault persists.
bi20e
- - 10 - -