5.2

Fault code descriptions

The fault codes that the user can correct themselves are given below. If a different
code appears, call a service technician.
Fault
Description
code
E 6
High temperature
The thermal overload cut-out has tripped.
The current welding process is stopped and cannot be restarted until the temperature has
fallen.
Action: Check that the cooling air inlets or outlets are not blocked or clogged with dirt.
Check the duty cycle being used, to make sure that the equipment is not being overloaded.
E 12
Communication error (warning)
The load on the system's CAN-bus is temporarily too high.
The power unit / wire feed unit has lost contact with the control panel.
Action: Check the equipment and ensure that only one wire feed unit or remote control
unit is installed. If the fault persists, send for a service technician.
E 17
Lost contact
The control panel has lost contact with the wire feed unit.
The current welding process stops.
Action: Check the cables. If the fault persists, send for a service technician.
E 18
Lost contact
The control panel has lost contact with the power source.
The current welding process stops.
Action: Check the cables. If the fault persists, send for a service technician.
E 27
Out of wire
The wire feed unit is not feeding out any wire. The current welding process will be stopped
and prevents welding start.
Action: Load a new wire.
E 29
No cooling water flow
The flow monitor switch has tripped.
The current welding process is stopped and starting is prevented.
Action: Check the cooling water circuit and the pump.
E 32
No gas flow
The gas flow is less than 6 l/min. Start prevented.
Action: Check the gas valve, hoses and connectors.
E 40
Incompatible units
Incorrect wire feed unit is connected. Start is prevented
Action: Connect the correct wire feed unit.
E 41
Lost contact with the cooling unit
The control panel has lost contact with the cooling unit. Switch off the power source!
Action: Check the wiring. If the fault persists, send for a service technician.