Service Technician Inspection; Storing The Turbofry 2000; Returning The Turbofry 2000 To Service After Storage - Pitco TurboFry 2000 Installation, Operation And Maintenance Manual

Hide thumbs Also See for TurboFry 2000:
Table of Contents

Advertisement

the groove. Make sure the O-Ring has seated in the bot-
tom of the groove and reinstall the Filter Bag Housing.
Oil Circulation Tube - There is an a-Ring inside the
housing where the Oil Circulation Tube seats. Use a
Curved Dental Pick to extract the O-Ring. Inspect it for
Dry, Cracked or Flat surfaces. To reinstall the O-Ring
Place the a-Ring in its groove making sure it is has not
twisted during the installation. If it did twist gently un-
twist it and replace it in the groove. Make sure the D-
Ring has seated in the bottom of the groove and reinstall
the Oil Circulation Tube.
Sump Screen - Unscrew the Sump Screen as described
in the Main Filter Bag Changing Procedure on page 12.
Inspect it for Dry, Cracked or Flat surfaces. To reinstall
the a-Ring place the a-Ring in its groove making sure it
is has not twisted during the installation. If it did twist
gently untwist it and replace it in the groove. Make sure
the a-Ring has seated in the bottom of the groove and
reinstall the Sump Screen Assembly.
Service Technicians
Ins~on:
On a yearly basis an Authorized Parts and Service Tech-
nician should perform the following Preventative Main-
tenance checks:
J
1.* Remove and clean or replace the Air Filter.
2. Perform recovery test.
3. Check input gas pressure.
4. Remove burner and inspect for sooting or other dam- Have the TURBOFRY 2(xx) checked out by an Autho-
age.
5. Check calibration of controls.
6. Remove and replace the Pump Suction Connection
O-Ring, Oil Circulation Tube O-Ring and the Sump
Screen O-Ring.
7.* Inspect the Filter Housing O-Ring, replace when
needed.
8. On machines equipped with Heaters, check to make
sure they are heating correctly.
9. * Inspect the Vacuum Gauge to make sure it is return-
ing to zero.
*
These are steps which the end user will normally
perfonn. however, during the Technician' scheduled
visit they are performed as part of the overall Pre-
ventative Maintenance (PM) service.
It is estimated that this should take approximately 2 - 2.5
hours.
Storina the TURBOFRY 2000:
If you need to store the TURBOFRY 2000 for an ex-
tended period of time. Please follow the guidelines be-
low:
Never leave oil (or solid shortening, if equipped for solid
shortening) in the fryer for longer than 7 days.
Boil out the fryer and operate the pump with fresh, clean
cooking oil to prevent corrosion from occurring inside
the pump.
Wipe up any oil spills around the front of the electrical
box.
Wash the Lower Pan and Lower Pan Pick Up Assembly
thoroughly.
Was the outside of the fryer with a heavy duty detergent
to remove any jelled cooking oil.
Shut off all gas and electric service to the fryer.
Returnina the TURBOFRY 2000 to service after
storage:
Reconnect the gas and electric service, and have them
tested by qualified Personnel.
rized Service and Parts (ASAP) technician.
If the storage was for longer than 7 days, the pump shaft
should be checked to see that it turns freely. If the pump
shaft does not turn freely, it must be freed up before at-
tempting to operate the TURBOFRY 2<XX>.
;17

Advertisement

Table of Contents
loading