Chapter 3: Operating Instruci'ions; Cornponent Recognition - Fry Tank - Pitco TurboFry 2000 Installation, Operation And Maintenance Manual

Hide thumbs Also See for TurboFry 2000:
Table of Contents

Advertisement

Chanter 3: OPERATING INSTRUCTIONS.
Comoonent Recomjtion
- Fn tank:
The Turbofry 2000 uses a new frying and filtering tech-
nology, therefore it is important that you become famil-
iar with the major components inside and outside of the
fry tank. The following drawing and index shows these
components and their uses:
1. Flue opening - The HOT exhaust gases from com-
bustion will rise from this opening.
6.
2. Burner Heat Tube
-
Combustion takes place within
this tube. The heat radiates out from this tube and 7.
from the sides of the fry tank.
3.
Hi Limit Probe
-
The Hi Limit is the safety device
that will shut the machine down should the tempera-
ture become excessively high.
Temperature Sensing Probe - This probe is used by
the Digital/Computer Control to sense the actual tem-
perature of the oil.
Oil Circulation Tube Assembly - The filtered oil is
returned to the fry tank through this tube. It has many
orifices along the underside to direct the oil streams
into the bottom of the fry tank. There is a handle
welded to the end of the tube.
Filter Bag Retainers - The Filter Bags "Hang" on the
retainer which fits snugly in the Filter Bag Housing.
Drain - Oil will drain from this opening when the
Drain Valve Handle is operated.
Filter Bag Housing Lifting Points - Use the supplied
lifting tool to lift the Housing out.
4.
5.
8.
5