60 Troubleshooting
Problem or error message
Error Code displayed on Display
Panel
Display Panel displays
Build Error
Display Panel displays
Can't Find Home –
Check Modeling
Base
Display Panel displays
Communication lost
at HR:MN UCT
Display Panel displays
Could Not Read
Cartridge
Display Panel displays
Load Failed
Dimension BST 1200 / SST 1200 User Guide
Solution
Re-configure settings per (see
Your Printer" on page 23
If using a Static network address, verify that the
IP address entered in CatalystEX has the same
value as the address entered for the printer.
Your system configuration may have changed.
Contact your Network Administator.
Call your local reseller for customer service. For
more information, refer to
Determination Codes" on page 61
Partial or bad part file sent to system. Check STL
file validity in CAD software; reprocess STL in
Catalyst and redownload to system.
Verify a modeling base is inserted.
Modeling base may be used or defective –
replace.
The system stopped reporting its status at the
Universal Coordinated Time (UCT) shown. Wait
for the system to complete building the part. The
system will automatically restart and display Build
Complete. It is then safe to remove the model.
Remove cartridge and cycle power (see
"Cycling Power" on page 31
cartridge.
Try a different cartridge.
Retry with same cartridge.
Try a different cartridge.
Filament may be jammed in extrusion head (see
"Loss of Extrusion" on page 61
"Networking
).
"Fault
.
); reload
).