Mounting
Transmitters may be attached directly to the sensor.
Mounting brackets also permit remote mounting. See
"Dimensional drawings" on page
Weight
Low-copper aluminum
Rosemount 648 Wireless without LCD display- 4.6 lbs.
(2 kg)
Rosemount 648 Wireless with M5 LCD display- 4.7 lbs
(2.1 kg)
Stainless steel
Rosemount 648 Wireless without LCD display- 8.0 lbs.
(3.6 kg)
Rosemount 648 Wireless with M5 LCD display- 8.1 lbs
(3.7 kg)
Enclosure ratings (Rosemount 648 Wireless)
Housing Style option codes D and E are Type 4X and
IP66/67 rated dual-compartment housings.
Table A-1. Temperature Limits
Operating limit
-4 to 175 °F
With LCD display
-20 to 80 °C
Without LCD
-40 to 185 °F
display
-40 to 85 °C
58
63.
Storage limit
-40 to 185 °F
-40 to 85 °C
-40 to 185 °F
-40 to 85 °C
Specifications and Reference Data
A.1.3 Performance specifications
EMC (ElectroMagnetic Compatibility)
All Models:
Meets all relevant requirements of EN 61326-1; 2006; EN
61326-2-3; 2006
Transmitter measurement stability
The Rosemount 648 Wireless has a stability of ±0.15% of
output reading or 0.15 °C (whichever is greater) for 24
months.
Self calibration
The analog-to-digital measurement circuitry automatically
self-calibrates for each temperature update by comparing
the dynamic measurement to extremely stable and
accurate internal reference elements.
Vibration effect
No effect when tested per the requirements of IEC60770-1:
High Vibration Level - field or pipeline (10–60 Hz 0.21 mm
displacement peak amplitude/60–2000 Hz 3 g).
July 2016