Configure Update Rate - Emerson Rosemount X-well 648 Reference Manual

Wireless temperature transmitter
Table of Contents

Advertisement

Reference Manual
00809-0200-4648, Rev BB
Figure 2-11. Smart Wireless Gateway Network Settings Page
2.6.3

Configure update rate

Fast Keys
The update rate is the frequency at which a new measurement is taken and transmitted
over the wireless network. This by default is one minute. This may be changed at
commissioning, or at any time via AMS Device Manager. The update rate is user selectable
from one second to 60 minutes.
1.
2.
3.
When the device configuration is completed, remove the power module and replace the
module cover. The power module should be inserted only when the device is ready to be
commissioned. Use caution when handling the power module.
Configuration
2, 1, 3
From the Home screen, select 2: Configure.
Select 1: Guided Setup.
Select 3: Configure Update Rate.
Configuration
July 2016
15