Warning
When you connect a device containing a coil, such as a relay or an
electromagnetic lock, it is necessary to protect the intercom against voltage
peak while switching off the induction load. For this way of protection we
recommend a diode 1 A / 1000 V (e.g., 1N4007, 1N5407, 1N5408) connected
antiparallel to the device.
Reset Button
Located among the main unit connectors, the Reset button helps you reset the factory
default values, restart the device, find the device IP address and switch the static
/dynamic mode.
Factory Reset (PCB version 555v5 and latest)
Follow the instructions below to
Press and hold the REST button.
Wait until the red and green LEDs on the device come on simultaneously
(approx. 20 s).
Wait until the red LED goes off (approx. 5 s).
Wait until the green LED goes off and the red LED comes on again (approx. 5 s).
Wait until the red LED goes off (another 5 s).
Release the RESET button.
2N TELEKOMUNIKACE a.s., www.2n.cz
reset the factory default values
:
58/117