In EtherCAT there are the following two types of error messages:
Emergency error message
n
n
Standard error message
Emergency error messages are generated on errors during state changes respectively at
hardware and diagnostic interrupts if the interrupt is activated by parameterization. Emer-
gency error messages are released within device-internal mechanisms and sent to the
master by means of the mailbox service.
Byte
0
1
EEC
EEC - Emergency Error Codes following ETG specifications:
0xFFxx: Vendor-specific emergency message (VIPA = 0xFF00)
0xA0xx: State Machine transition error, e.g. due to a configuration error (length,
address, settings). More information concerning this may be found at ETG.
ER
- Error register - State of the State Machine:
01: Init
02: Pre-Op
03: BootStrap
04: Safe-Op
08: Op
DATA - Error data with more information concerning the error
With a hardware interrupt or diagnostic interrupt respectively in DATA the Manufacturer
Specific Error Field (MEF) may be found. The field has the following structure:
Byte
0
1
EEC
SLOT - EtherCAT-Slot of the module where is the error from
TYPE - Interrupt type
01: Hardware interrupt
02: Diagnostics interrupt
DIAG - Error code, which is described at corresponding module.
2
3
4
ER
2
3
4
ER
SLOT
TYPE
VIPA System SLIO
5
6
DATA
5
6
DIAG
MEF
HB300 | IM | 053-1EC01 | en | 18-49