Connections; Power Supply (X201) - Danfoss ISD Encoder Box Operating Instructions Manual

Table of Contents

Advertisement

Description
No.
Name
1
ISD Power Supply Module
2
ISD Connection Box
3
Feed cable
4
Terminating resistor
5
ISD Encoder Box
6
Master
4
4
7
Control Cabinet
Ethernet
CAN line
Encoder line
Loop cable
DC cable
AC feed
Table 4.3 Legend to Illustration 4.3

4.3.3 Connections

SD Card
ISD Encoder Box
Run/Err
Power
CAN I
CAN II
Power
CAN I
in
X201
X501
Illustration 4.4 Connections on the ISD Encoder Box
Inscription
Power
CAN I (in / out) Connection CAN line I
CAN II (in / out) Connection CAN line II
RS 422-I
RS 422-II
SD
Table 4.4 Connections on the ISD Encoder Box
14
VLT
Line Type
Hybrid cable (DC & CAN)
Connector with terminating
resistor
Ethernet cable
CAN cable (screened)
Encoder cable
Hybrid cable (DC & CAN)
Single wire
Single wire
CAN-ID
4
6
2
8
0
Set
Warn
Err
CAN II
RS 422
out
in
out
X502
X601
Function
24 V Power supply
Connection encoder I
Connection encoder II (currently
not in use)
SD card slot
MG75F102 - VLT
®
ISD Encoder Box Operating Instructions
Cross-section
1/2.5 mm
4 x 2 x 0.27 mm², shielded
twisted pairs (CAT 5)
4 x 0.25 mm
4 x 0.25 mm
1/2.5 mm
2
1.5 mm
1.5 mm
2
4.3.3.1 24 V Power Supply (X201)
RS232
Service
X602
Illustration 4.5 24 V Housing and Plug
Designation
X201
X501
Pin Signal
X502
1
GND_24 V Power Supply Input (DC Ground) 1 mm
X601
2
FE
X602
3
+24 V
Table 4.5 Connector Pin Assignment
®
is a registered Danfoss trademark
Flexible Cable
2
X (only with 2.5 mm
X
2
2
2
X (only with 2.5 mm
Description
Functional- Earth connection
Power Supply Input (DC 24 V)
2
)
2
)
Cross-Section
2
2
1 mm
2
1 mm