Code
Description
14,96
Unidentified interrupt
occurred
14,97
Invalid data type
14,98
Find home failed, X EOT time-
out
14,99
Find home failed, Y EOT time-
out
14,100
Find home failed, Z HOME
(BOT) not tripped
14,101
Find home failed, Z EOT not
tripped
14,102
Find home failed, Z HOME
(BOT) time-out
14,103
Find home failed, Z EOT time-
out
14,104
Surface not found
14,105
Controller not ready to build a
model
14,106
BOT offset is higher than the
BOT switch
14,107
End model command while
not modeling
14,108
Operation was killed
14,109
Out of memory
14,110
Cartridge communication
error
14,111
Invalid frame check sequence
14,112
EEPROM communication error
14,113
Door not latched
14,114
Thermocouple snap switch
tripped
14,115
Z stage planarity beyond toler-
ance
14,116
I2C configuration info is cor-
rupt
14,117
A command failed while mod-
eling
14,118
Invalid cyclic redundancy
check
uPrint/uPrint SE Service Manual
Corrective Actions
1.
Cycle power.
1.
Cycle power.
1.
Power cycle machine - remember to move head away from switches.
2.
Using LED's check to see limit box toggles when switch is activated. If
not, check switch and/or umbilical cable for X, Y cable for Y.
3.
X errors - Check pins and re-seat connector J505 on the I/O Card. Y
errors - Check pins and re-seat connector J503 on the I/O Card.
1.
Check for objects/parts on Z stage and around lead screw.
2.
Cycle power.
3.
Check Z Home and Z EOT LED's on PDB to verify state changes
correctly. If not, check connector P8 on the PDB and Z switches.
Replace cable and/or switches.
4.
Replace Z axis motor and lead screw.
5.
14.101 error only - Check 5/12 VDC power (5 and 12VDC LEDs will
repeatedly dim) Replace 5/12 VDC power supply.
1.
No modeling base. Install modeling base.
2.
Modeling base is used/defective, has low spot. Replace Modeling
base.
3.
Verify substrate sensor is working. If not, replace Substrate Sensor.
1.
Cycle power.
1.
Use MaracaEX to zero the Z offset value.
2.
Run tip Z calibration.
3.
Check Z home sensor.
Software error; will not be displayed.
Software error; will not be displayed.
Software error; will not be displayed.
1.
Replace material spool.
2.
Replace material carrier.
3.
Replace material bay.
1.
Cycle power.
2.
If error repeats, replace Controller Board.
Software error; will not be displayed.
1.
Verify chamber fans are operational. If not, replace 24VDC power
supply.
2.
Inspect solenoid and wiring.
3.
Replace solenoid.
4.
Replace PDB.
Not used on uPrint, uPrint SE, uPrint Plus and uPrint SE Plus printers.
1.
Replace modeling base.
2.
Re-level XY table.
Software error; will not be displayed.
1.
Download CFG file - check error code details.
2.
Toggle failure - reference 14,129.
3.
Check and re-seat connectors/pins on J506 on the I/O card and J301
on the head board.
4.
Replace Toggle Head assembly.
5.
Replace PDB (U8 chip failure).
Software error; will not be displayed