Stratasys uPrint Service Manual page 232

Hide thumbs Also See for uPrint:
Table of Contents

Advertisement

9.
Using a digital caliper, measure and record the diameter of circle B along the center line
between A and C. See
Note: Reference letters are not actually "printed" on the part. If needed, use the
Part Measurement Equations sheet to record the values. See
Equations on page 5-36.
10.
Next measure and record the distance from the outside edges of circle A and B, see
Figure 5-316.
Figure 5-316: Measuring distance from outside edges of A and B
11.
Next measure and record the distance from the outside edges of circle B and C, see
5-317.
Ensure that the caliper is not seated on the small bump of circle C.
Figure 5-317: Measuring distance from outside edges of B and C
12.
Add the lengths derived from steps
of circle B. Record this total as "GFront"
13.
Measure and record the distance from the outside edges of circles E and F. Ensure the
caliper is not seated on the small bump of circle E. See
uPrint/uPrint SE Service Manual
Figure 5-315.
Figure 5-315: Measuring diameter of B
Ensure that the caliper is not seated on the small bump of circle A.
9
and
10
(A-B and B-C) and then subtract the width
Figure 5-318.
Part Measurement
Figure
5-23