Quick Start Guide
NOTICE
This installation guide provides basic guidelines for the Rosemount 4088 MultiVariable
Transmitter (reference manual document number 00809-0100-4088). It does not provide
instructions for diagnostics, maintenance, service, or troubleshooting. Refer to the 4088
MultiVariable Transmitter Reference Manual for more instruction. All documents are available
electronically at www.emersonprocess.com/rosemount.
Procedures and instructions in this section may require special precautions to
ensure the safety of the personnel performing the operation. Information that
raises potential safety issues is indicated with a warning symbol (
following safety messages before performing an operation preceded by this
symbol.
Explosions could result in death or serious injury.
Installation of this transmitter in an explosive environment must be in accordance with the
appropriate local, national, and international standards, codes, and practices. Review the
approvals section of the 4088 MultiVariable Transmitter Reference Manual (00809-0100-4088)
for any restrictions associated with a safe installation.
Before connecting any instruments in an explosive atmosphere, ensure any instruments in the
loop are installed in accordance with intrinsically safe or non-incendive field wiring practices.
In an Explosion-proof/Flameproof installation, do not remove the transmitter covers when
power is applied to the unit.
Process leaks may cause harm or result in death.
Install and tighten process connectors before applying pressure.
Electrical shock can result in death or serious injury.
Avoid contact with the leads and terminals. High voltage that may be present on leads can
cause electrical shock.
Conduit/cable entries
Unless marked, the conduit/cable entries in the transmitter housing use a 1/2-14 NPT thread
form. Entries marked "M20" are M20 x 1.5 thread form. On devices with multiple conduit
entries, all entries will have the same thread form. Only use plugs, adapters, glands, or conduit
with a compatible thread form when closing these entries.
When installing in a hazardous location, use only appropriately listed or Ex certified plugs,
adapters, or glands in cable/conduit entries.
Contents
Mount the transmitter . . . . . . . . . . page 4
Consider housing rotation . . . . . . . page 8
Set the switches . . . . . . . . . . . . . . . . page 9
2
Wiring and power up . . . . . . . . . . . .page 9
Verify device configuration . . . . . page 15
Trim the transmitter . . . . . . . . . . . page 16
Product Certifications . . . . . . . . . . page 17